XMTA-AC100 Instruction manual of ammeter

Back to list

Product descriptionTechnical indexApplication fieldDownload


★ Before using this product, please read the instructions carefully for proper use and keep them for reference at any time.

?Operation Precautions?

 

1、The instrument can be cleaned after power off.

2、Remove stains on the monitor with a soft cloth or tissue paper.

3、Monitor is easy to be scratched, do not wipe or touch with hard objects.

4、Do not use an object such as a screwdriver or writing pen to operate the keys on the panel; otherwise, the keys may be damaged or scratched.

ONE、Main technical indicators

 The test object of XMTA-AC100 ammeter is 45 ~ 65Hz AC current signal, and the product meets the requirements《DB37/T557-2005 The specific technical indexes of digital electric parameter measuring (testing) 》instrument are as follows.

1、Working power supply:AC220V±10%,50/60Hz

2、The measured parameters : Ac current, maximum range 5A

3、The basic error:  4%Apparent value + 1%range

4、resolving power :0.001A

5、Allow overload :120%×Maximum range

6、Accuracy of measurement:0.5 Level

7、The update frequency:About 3Hz

8、The machine power consumption:< 4W

9、Overall dimensions:80(H)×160(W)×94(D)

10、The weight: About 500g

11、The work environment:environment temperature 0~50°C,atmospheric pressure 86~106kPa、relative humidity :20~90%RH

Note: the above indicators are common product indicators, customized products are subject to the customer order contract.

TWO、Optional extension functions (customized according to customer requirements)

1、Serial communication: Isolation of RS485

2、Relay output:Output contact capacity of relay is 5A/30VDC or 5A/250VAC

3、Analog output:0~20mA、4~20mA,0~5VDC、1~5VDC、0~10VDC、1~10VDC, Analog input impedance≤800Ω

THREE、Description of panel layout and wiring terminal diagram

1、Panel layout

圖片1.png